Nissan Rogue (T33) 2021-Present Service Manual: P1c91-14 Sub Starter & Generator
DTC Description
DTC DETECTION LOGIC
| DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC detection condition | |
|---|---|---|---|
| P1C91-14 |
Sub starter & generator (Sub starter & generator) |
Diagnosis condition | Engine running at idle |
| Signal (terminal) | Battery voltage | ||
| Threshold | Less than 5.5 V, or more than 17.5 V | ||
| Diagnosis delay time | 1 second or less | ||
POSSIBLE CAUSE
-
Harness or connectors (“B” terminal circuit is open or shorted.)
-
Harness or connectors (Ground circuit is open or shorted.)
-
Fusible link
-
Sub starter & generator
FAIL-SAFE
Stop the operation of sub starter & generator
DTC CONFIRMATION PROCEDURE
PERFORM DTC CONFIRMATION PROCEDURE
CONSULT
-
Start the engine and let it idle and wait for 1 second or more.
-
Select “Self diagnosis result” mode of “Sub starter & generator”.
Is DTC detected?
YES>>Refer to Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: Inspection End.
Diagnosis Procedure
CHECK “B” TERMINAL CONNECTION
-
Ignition switch OFF.
-
Check if “B” terminal is clean and tight.
Is the inspection result normal?
Yes>>GO TO 2.
NO>>Repair “B” terminal connection.
CHECK FUSIBLE LINK
-
Ignition switch OFF.
-
Check that the following fusible link is not blowing:
Location Fusible link Capacity BATTERY TERMINAL WITH FUSIBLE LINK A 450A
Is the fusible lnk blown (open)?
YES>>Replace the fusible link after repairing the applicable circuit.
NO>>GO TO 3.
CHECK SUB STARTER & GENERATOR “B” TERMINAL VOLTAGE
-
Disconnect “B” terminal of sub starter & generator.
-
Check the voltage between the “B” terminal and ground.
(+) (-) Voltage
(Approx.)Sub starter & generator Connector Terminal F125 (without ProPILOT Assist 2.1) 7 Ground Battery voltage F129 (with ProPILOT Assist 2.1) 7 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK GROUND CIRCUIT
Check continuity between sub starter & generator harness connector and ground.
| (+) | (-) | Continuity | |
|---|---|---|---|
| Sub starter & generator | |||
| Connector | Terminal | ||
| F126 | 5 | Ground | Yes |
Is the inspection result normal?
YES>>Replace sub starter & generator. Refer to Removal and Installation.
NO>>Repair or replace harness.
Other materials:
Diagnosis System (adas Control Unit 2)
Without Propilot Assist 2.1
Diagnosis Description
APPLICATION ITEMSCONSULT performs the following functions via CAN communication using ADAS control unit 2. Diagnosis mode CGW Status Description
Restricted Mode Diag Test Mode Open Mode
Self Diagnostic Result
Display
Display
Di ...
U288c-88 Ethernet Circuit
DTC Description
DTC DETECTION LOGIC DTC No. CONSULT screen terms DTC detected condition
U288C-88
Ethernet circuit
Diagnosis condition
When ignition switch is ON.
Signal (terminal)
—
Threshold
Lost ethernet communication with combination meter and/or Head Up Display u ...
Dtc/circuit Diagnosis. C1700-54 Control Unit
DTC Description
NOTE:
The Signal Tech II Tool [– (NI-50190)] can be used to
perform the following functions: Refer to the Signal Tech II User Guide
for additional information.
Activate and display TPMS sensor IDs
Display tire pressure reported by the TPMS sensor
Read TPMS DTCs ...