Nissan Rogue (T33) 2021-Present Service Manual: Evap Control System Pressure Sensor
Component Inspection
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
-
Turn ignition switch OFF.
-
Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
-
Install a vacuum pump to EVAP control system pressure sensor.
-
Turn ignition switch ON and check output voltage between ECM harness connector and ground under the following conditions.
ECM Condition
[Applied vacuum kPa (bar, kg/cm2, psi)]Voltage Connector + − Terminal E21 129 155 Not applied 0.5 – 4.6 V −26.7 (−0.3, −0.272, −3.87) 2.1 to 2.5 V lower than above value CAUTION:
-
Always calibrate the vacuum pump gauge when using it.
-
Never apply below −93.3 kPa (−0.9 bar, −0.952 kg/cm2, −13.53 psi) or pressure over 101.3 kPa (1.0 bar, 1.033 kg/cm2, 14.69 psi).
-
Is the inspection result normal?
YES>>INSPECTION END
NO>>Replace EVAP control system pressure sensor. Refer to Exploded View.
Other materials:
Transfer: Ty92a. Basic Inspection
Diagnosis and Repair Work Flow
Work Flow
DETAILED FLOWINTERVIEW FROM THE CUSTOMER
Clarify customer complaints before inspection. First of all, perform
an interview utilizing Diagnostic Work Sheet and reproduce symptoms as
well as fully understand it. Ask customer about his/her complaints
ca ...
Power Supply and Ground Circuit
Combination Meter
Diagnosis Procedure
CHECK FUSE
Check that the following fuses are not blown:
Unit Location Fuse No. Capacity
Combination meter
Fuse block (J/B)
29
5A
6
5A
Is the fuse blown?
YES>>
Replace the blown fuse after repairing the affected circu ...
Illumination Control Switch Signal Circuit
Component Function Check
CHECK COMBINATION METER INPUT SIGNAL
Ignition switch ON.
Measure voltage between the following terminals of the combination meter.
Combination meter
Condition
Voltage
(Approx.)
Connector
Terminals
(+)
(−)
M76