Front Lh

Diagnosis Procedure

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

  1. Ignition switch OFF.

  2. Disconnect front door lock assembly LH connector.

  3. Check voltage between front door lock assembly LH harness connector and ground.

    (+) (–) Condition

    Voltage

    (Approx.)
    Front door lock assembly LH
    Connector Terminal
    D23 1 Ground Door lock/unlock switch Unlock Battery voltage
    2 Lock

Is the inspection result normal?

YES>>

Replace front door lock assembly LH. Refer to Removal and Installation.

NO>>

GO TO 2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

  1. Disconnect BCM and rear door lock assembly LH connector.

  2. Check continuity between BCM harness connector and front door lock assembly LH harness connector.

    With Type B Meter
    BCM Front door lock assembly LH Continuity
    Connector Terminal Connector Terminal
    B23 134 D23 1 Yes
    142 2
    With Type A Meter
    BCM Front door lock assembly LH Continuity
    Connector Terminal Connector Terminal
    B124 134 D23 2 Yes
    143 1
  3. Check continuity between BCM harness connector and ground.

    With Type B Meter
    BCM Continuity
    Connector Terminal
    B23 134 Ground No
    142
    With Type A Meter
    BCM Continuity
    Connector Terminal
    B124 134 Ground No
    143

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness.

CHECK BCM OUTPUT SIGNAL

  1. Connect BCM connector.

  2. Check voltage between BCM harness connector and ground.

With Type B Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B23 134 Ground Door lock/unlock switch Unlock Battery voltage
142 Lock
With Type A Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B124 134 Ground Door lock/unlock switch Unlock Battery voltage
143 Lock

Is the inspection result normal?

YES>>

Check for internal short of front door lock actuator.

NO>>

Replace BCM. Refer to Removal and Installation.

Front Rh

Diagnosis Procedure

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

  1. Ignition switch OFF.

  2. Disconnect front door lock assembly RH connector.

  3. Check voltage between front door lock assembly RH harness connector and ground.

    (+) (–) Condition

    Voltage

    (Approx.)
    Front door lock assembly RH
    Connector Terminal
    D113 3 Ground Door lock/unlock switch Unlock Battery voltage
    4 Lock

Is the inspection result normal?

YES>>

Replace front door lock assembly RH. Refer to Removal and Installation.

NO>>

GO TO 2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

  1. Disconnect BCM and rear door lock assembly RH connector.

  2. Check continuity between BCM harness connector and front door lock assembly RH harness connector.

    With Type B Meter
    BCM Front door lock assembly RH Continuity
    Connector Terminal Connector Terminal
    B23 132 D113 3 Yes
    B27 154 4
    With Type A Meter
    BCM Front door lock assembly RH Continuity
    Connector Terminal Connector Terminal
    B124 133 D113 3 Yes
    B125 153 4
  3. Check continuity between BCM harness connector and ground.

    With Type B Meter
    BCM Continuity
    Connector Terminal
    B23 132 Ground No
    B27 154
    With Type A Meter
    BCM Continuity
    Connector Terminal
    B124 133 Ground No
    B125 153

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness.

CHECK BCM OUTPUT SIGNAL

  1. Connect BCM connector.

  2. Check voltage between BCM harness connector and ground.

With Type B Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B23 132 Ground Door lock/unlock switch Unlock Battery voltage
B27 154 Lock
With Type A Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B124 133 Ground Door lock/unlock switch Unlock Battery voltage
B125 153 Lock

Is the inspection result normal?

YES>>

Check for internal short of front door lock actuator.

NO>>

Replace BCM. Refer to Removal and Installation.

Rear Lh

Diagnosis Procedure

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

  1. Ignition switch OFF.

  2. Disconnect rear door lock assembly LH connector.

  3. Check voltage between rear door lock assembly LH harness connector and ground.

    (+) (–) Condition

    Voltage

    (Approx.)
    Rear door lock assembly LH
    Connector Terminal
    D206 1 Ground Door lock/unlock switch Unlock Battery voltage
    2 Lock

Is the inspection result normal?

YES>>

Replace rear door lock assembly LH. Refer to Removal and Installation.

NO>>

GO TO 2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

  1. Disconnect BCM connector, front door lock assembly LH connector and rear door lock assembly RH connector.

  2. Check continuity between BCM harness connector and rear door lock assembly LH harness connector.

    With Type B Meter
    BCM Rear door lock assembly LH Continuity
    Connector Terminal Connector Terminal
    B23 142 D206 2 Yes
    B27 155 1
    With Type A Meter
    BCM Rear door lock assembly LH Continuity
    Connector Terminal Connector Terminal
    B124 134 D206 2 Yes
    B125 154 1
  3. Check continuity between BCM harness connector and ground.

    With Type B Meter
    BCM Continuity
    Connector Terminal
    B23 142 Ground No
    B27 155
    With Type A Meter
    BCM Continuity
    Connector Terminal
    B124 134 Ground No
    B125 154

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness.

CHECK BCM OUTPUT SIGNAL

  1. Connect BCM connector.

  2. Check voltage between BCM harness connector and ground.

With Type B Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B23 142 Ground Door lock/unlock switch Lock Battery voltage
B27 155 Unlock
With Type A Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B124 134 Ground Door lock/unlock switch Lock Battery voltage
B125 154 Unlock

Is the inspection result normal?

YES>>

Check for internal short of rear door lock actuator.

NO>>

Replace BCM. Refer to Removal and Installation.

Rear Rh

Diagnosis Procedure

CHECK DOOR LOCK ACTUATOR INPUT SIGNAL

  1. Ignition switch OFF.

  2. Disconnect rear door lock assembly RH connector.

  3. Check voltage between rear door lock assembly RH harness connector and ground.

    (+) (–) Condition

    Voltage

    (Approx.)
    Rear door lock assembly RH
    Connector Terminal
    D306 3 Ground Door lock/unlock switch Unlock Battery voltage
    4 Lock

Is the inspection result normal?

YES>>

Replace rear door lock assembly RH. Refer to Removal and Installation.

NO>>

GO TO 2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

  1. Disconnect BCM connector, rear door lock assembly LH connector and front door lock assembly RH connector.

  2. Check continuity between BCM harness connector and rear door lock assembly RH harness connector.

    With Type B Meter
    BCM Rear door lock assembly RH Continuity
    Connector Terminal Connector Terminal
    B27 154 D306 4 Yes
    155 3
    With Type A Meter
    BCM Rear door lock assembly RH Continuity
    Connector Terminal Connector Terminal
    B125 153 D306 4 Yes
    154 3
  3. Check continuity between BCM harness connector and ground.

    With Type B Meter
    BCM Continuity
    Connector Terminal
    B27 154 Ground No
    155
    With Type A Meter
    BCM Continuity
    Connector Terminal
    B125 153 Ground No
    154

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace harness.

CHECK BCM OUTPUT SIGNAL

  1. Connect BCM connector.

  2. Check voltage between BCM harness connector and ground.

With Type B Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B27 154 Ground Door lock/unlock switch Lock Battery voltage
155 Unlock
With Type A Meter
(+) (–) Condition

Voltage

(Approx.)
BCM
Connector Terminal
B125 153 Ground Door lock/unlock switch Lock Battery voltage
154 Unlock

Is the inspection result normal?

YES>>

Check for internal short of rear door lock actuator.

NO>>

Replace BCM. Refer to Removal and Installation.

    Dtc/circuit Diagnosis. Back Door Request Switch
    Component Inspection CHECK BACK DOOR REQUEST SWITCH Ignition switch OFF. Disconnect back door opener switch connector. Check back door opener switch terminals. Back door opener ...
    Dtc/circuit Diagnosis. Door Lock/unlock Switch
    Front Lh Component Function Check CHECK FUNCTION CONSULT Ignition switch ON. Select “Door lock and unlock switch (lock)”, “Door lock and unlock switch (unlock)” in “Da...

    Other materials:

    Cvt: Ge0f14a. Symptom Diagnosis
    Cvt Control System Symptom Table The diagnosis item number indicates the order of check. Start checking in the order from 1. Perform diagnoses of symptom table 1 before symptom table 2. Symptom Table 1 Diagnostic item Reference Symptom Shift Shock Slips/Will Not Engage Other ...

    Main Line Between Lib 12v and M&a Circuit
    Diagnosis Procedure CHECK CONNECTOR Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Check the following terminals and connectors for damage, bend and loose connection (connector side and harness side). Harness connector B41 Harness con ...

    Brake fluid
    For more information on brake fluid type and capacity, refer to “Capacities and recommended fluids/lubricants”. WARNING Always use new brake fluid from a sealed container. Contaminated, old, or poor-quality fluid may damage the brake system and reduce stopping performance. Clean the filler c ...