Nissan Rogue (T33) 2021-Present Service Manual: Throttle Valve Closed Position Learning
Description
Throttle Valve Closed Position Learning is a function of ECM to learn the fully closed position of the throttle valve by monitoring the throttle position sensor output signal. It must be performed each time the harness connector of the electric throttle control actuator or ECM is disconnected or electric throttle control actuator inside is cleaned.
Work Procedure
START
With CONSULT
-
Turn ignition switch ON.
-
Select “Close throttle position learning” in “WORK SUPPORT” mode of “ENGINE” using CONSULT.
-
Follow the instructions on the CONSULT display.
-
Turn ignition switch OFF and wait at least 10 seconds.
Check that throttle valve moves during the above 10 seconds by confirming the operating sound.
Without CONSULT
-
Start the engine.
NOTE:
Engine coolant temperature is 25°C (77°F) or less before engine starts.
-
Warm up the engine until engine coolant temperature reaches more than 65°C (149°F).
-
Turn ignition switch OFF and wait at least 10 seconds.
Check that throttle valve moves during the above 10 seconds by confirming the operating sound.
>>
END
Other materials:
B24a2-55 Configuration Not Implement
DTC Description
DTC DETECTION LOGIC DTC No.
CONSULT screen terms
(Trouble diagnosis content) DTC detection condition
B24A2-55
Configuration not implement
(Configuration not implement)
Diagnosis condition
Ignition switch ON
Signal (Terminal)
—
Threshold
Nissan Ari ...
Removal and Installation. Drain Hose
Exploded View
Refer to Exploded View.
Removal and Installation
REMOVALFrontRemove headlining. Refer to Removal and Installation.
Remove front drain connector. Refer to Removal and Installation.
Remove front drain hose from moonroof unit assembly.RearRemove headlining. Refer to Removal and Insta ...
Dtc/circuit Diagnosis. Power Supply and Ground Circuit
Moonroof Motor Assembly
Diagnosis Procedure
CHECK FUSE
Ignition switch OFF.
Check that the following fuse is not blown (open):
Fuse No. Capacity
31
15 A
Is the fuse blown (open)?
YES>>