Nissan Rogue (T33) 2021-Present Service Manual: Symptom Diagnosis :: Moonroof Does Not Operate Properly
Description
Moonroof does not operate normally.
-
Moonroof tilt up/down, open/close does not operate.
-
Moonroof tilt up/down, open/close operation is slow.
-
Judder occurs during open/close operation of moonroof.
Diagnosis Procedure
CHECK MOONROOF UNIT ASSEMBLY
Check the following items:
-
Damage, deformation or trapped foreign material of slide rail.
-
Insufficient application of grease to sliding section of slide rail.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace the malfunctioning parts.
CHECK MOONROOF MOTOR ASSEMBLY POWER SUPPLY AND GROUND CIRCUIT
Check moonroof motor assembly power supply and ground circuit.
Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace the malfunctioning parts.
CHECK LIN COMMUNICATION CIRCUIT
Check LIN communication circuit. Refer to Diagnosis Procedure.
YES>>
GO TO 4.
NO>>Repair or replace the malfunctioning parts.
CHECK MOONROOF SWITCH
Check moonroof switch.
Refer to Component Function Check.
Is the inspection result normal?
YES>>Replace moonroof motor assembly. Refer to Removal and Installation.
NO>>Repair or replace the malfunctioning parts.
Other materials:
Steering Assist
Basic information
Steering Assist is a part of the ProPILOT Assist Systems available on the Nissan Rogue. Read the entire ProPILOT Assist section before using this system, including how to operate it and how to understand the display information.
Steering Assist uses a forward-facing camera to detec ...
Air Cleaner and Air Duct
Exploded View
1.
Air duct (Inlet)
2.
Clip
3.
Mounting rubber
4.
Mounting rubber
5.
Bracket
6.
Clip
7.
Air cleaner body
8.
Mounting rubber
9.
Collar
10.
Air cleaner filter
11.
Air cleaner cover
12.
Mass air flow sensor
...
Writing of Calibration Data
Work Procedure
DESCRIPTIONIf only the around view monitor control unit
is replaced, the calibration data stored in the camera can be written
to the around view monitor control unit by selecting "Camera
Calibration" of "Work Support" mode in CONSULT.WORK PROCEDUREWRITE CALIBRATION DATA
With C ...