Nissan Rogue (T33) 2021-Present Service Manual: Symptom Diagnosis :: Interior Lighting System Symptoms
Symptom Table
NOTE:
Perform self diagnosis result with CONSULT before the symptom diagnosis. Perform the trouble diagnosis if any DTC is detected.
| Symptom | Possible cause | Inspection item |
|---|---|---|
|
All the following lamps do not turn ON:
|
|
Interior room lamp power supply circuit Refer to Diagnosis Procedure. |
|
Any of the following lamp does not turn ON:
|
|
Map lamp control circuit Refer to Component Function Check. |
|
Room lamp control circuit Refer to Component Function Check. |
|
|
Personal lamp control circuit Refer to Component Function Check. |
|
|
|
Door switch circuit Refer to Component Function Check. |
|
Map lamp control circuit Refer to Component Function Check. |
|
|
|
Room lamp control circuit Refer to Component Function Check. |
|
|
Personal lamp control circuit Refer to Component Function Check. |
|
|
Mood lamp control circuit Refer to Component Function Check. |
|
|
Ajar switch circuit Refer to Component Function Check . |
|
Luggage room lamp control circuit Refer to Component Function Check. |
|
| Vanity mirror lamp does not turn ON. |
|
Vanity mirror lamp control circuit Refer to Diagnosis Procedure. |
| Push-button ignition switch illumination does not illuminate. |
|
Push-button ignition switch illumination control circuit Refer to Diagnosis Procedure. |
| Interior room lamp battery saver does not activate. |
|
Interior room lamp power supply circuit Refer to Diagnosis Procedure. |
Other materials:
P0182 Ftt Sensor
DTC Description
DTC DETECTION LOGIC DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
P0182
00
FTT SEN/CIRCUIT
(Fuel temperature sensor ″A″ circuit low)
Diagnosis condition
Ignition switch ON
Signal (terminal)
Fuel tank temperature s ...
P0454 Evap System Pressure Sensor
DTC Description
DTC DETECTION LOGIC DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
P0454
00
EVAP SYS PRES SEN
(EVAP system pressure sensor/switch "A" circuit intermittent)
Diagnosis condition
—
Signal (terminal)
EVAP control system ...
Kr15ddt. Basic Inspection
Diagnosis and Repair Workflow
Work Flow
OVERALL SEQUENCEDETAILED FLOWINTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
>>
GO TO 2.
SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the interviewed symptom.
Insu ...