Nissan Rogue (T33) 2021-Present Service Manual: Symptom Diagnosis :: Electric Power Steering Warning Lamp Does Not Turn Off

Nissan Rogue (T33) 2021-Present Service Manual / Steering :: Steering Control System / Symptom Diagnosis :: Electric Power Steering Warning Lamp Does Not Turn Off

Description

Power steering warning lamp does not turn OFF several seconds after engine started.

Diagnosis Procedure

PERFORM SELF-DIAGNOSIS

CONSULT

Perform self diagnosis for “EPS/Direct Adaptive Steering 3”.

Is any DTC detected?

YES>>

Check the DTC. Refer to DTC Index.

NO>>

GO TO 2.

CHECK POWER STEERING WARNING LAMP

Perform the trouble diagnosis of power steering warning lamp. Refer to Component Function Check.

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace power steering warning lamp system.

POWER STEERING CONTROL MODULE POWER SUPPLY AND GROUND CIRCUIT

Perform the trouble diagnosis of power steering control module power supply and ground. Refer to Diagnosis Procedure.

Is the inspection result normal?

YES>>

Check that the terminals and the connection of each connector are normal.

NO>>

Repair / replace harness, connector, terminal, fuse, or fusible link.

    Symptom Diagnosis. Electric Power Steering Warning Lamp Does Not Turn on
    Description The power steering warning lamp does not illuminate when the ignition switch is ON (lamp check). Diagnosis Procedure CHECK THE POWER STEERING WARNING LAMP Perform tr...
    Symptom Diagnosis. Steering Wheel Turning Force Is Heavy or Light
    Description Steering wheel turning force is heavy or light. Diagnosis Procedure PERFORM SELF-DIAGNOSIS CONSULT Pull the parking brake switch. NOTE: Check to make sure that the p...

    Other materials:

    P2c91 Crankcase Ventilation System
    DTC Description DTC DETECTION LOGIC DTC CONSULT screen terms (Trouble diagnosis content) DTC detection condition P2C91 00 Crankcase Ventilation System - Hose "B" Disconnected (Crankcase Pressure Sensor "A" Circuit Low) Diagnosis condition Ignition switch ON Inta ...

    Symptom Diagnosis. Driver Side Power Window Does Not Operate
    Diagnosis Procedure CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT Check power window main switch power supply and ground circuit. Refer to Diagnosis Procedure. Is the inspection result normal? YES>> GO TO 2. NO>> Repair or replace the malfunctioning parts. CHE ...

    Mixture Ratio Self-Learning Value Clear
    Description This describes how to erase the mixture ratio self-learning value. For the actual procedure, follow the instructions in “Diagnosis Procedure”. (For details, refer to Work Procedure.) Work Procedure START With CONSULT Start engine and warm it up to normal operating tempe ...