Nissan Rogue (T33) 2021-Present Service Manual: Stop Lamp Relay Circuit
Diagnosis Procedure
CHECK STOP LAMP OPERATION
Check that stop lamp is turned ON/OFF when the brake pedal is depressed/released.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Check stop lamp circuit. Refer to Component Function Check.
CHECK STOP LAMP RELAY FUSE
Check that the following fuse is not blown (open):
| Unit | Location | Fuse No. | Capacity |
|---|---|---|---|
| Ignition switch power supply | Fuse and fusible link box 6 | 116 | 10 A |
Is the fuse blown (open)?
YES>>Replace the blown (open) fuse after repairing the affected circuit if a fuse is blown (open).
NO>>GO TO 3.
CHECK STOP LAMP RELAY POWER SUPPLY CIRCUIT
-
Disconnect stop lamp relay connector.
-
Ignition switch ON.
-
Check voltage between stop lamp relay harness connector and ground.
+ - Voltage
(Approx.)Stop lamp relay Connector Terminal E148 1 Ground Battery voltage 3
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK STOP LAMP RELAY
Check stop lamp relay. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace stop lamp relay.
CHECK STOP LAMP RELAY CONTROL SIGNAL CIRCUIT
-
Ignition switch OFF.
-
Disconnect chassis control module connector.
-
Check continuity between chassis control module harness connector and stop lamp relay harness connector.
Chassis control module Stop lamp relay Continuity Connector Terminal Connector Terminal M32 32 E148 4 Yes -
Check continuity between chassis control module harness connector and ground.
Chassis control module — Continuity Connector Terminal E32 32 Ground No
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace harness.
CHECK STOP LAMP POWER SUPPLY CIRCUIT 1
-
Disconnect rear combination lamp (body side) connector.
-
Check continuity between rear combination lamp (body side) harness connector and stop lamp relay harness connector.
Rear combination lamp (body side) Stop lamp relay Continuity Connector Terminal Connector Terminal RH B102 3 E148 2 Yes LH B90 -
Check continuity between stop lamp relay harness connector and ground.
Stop lamp relay — Continuity Connector Terminal E148 2 Ground No
Is the inspection result normal?
YES>>Replace chassis control module. Refer to Removal and Installation.
NO>>Repair or replace harness.
Component Inspection
CHECK STOP LAMP RELAY
-
Ignition switch OFF.
-
Disconnect stop lamp relay connector.
-
Check continuity between stop lamp relay terminals.
Stop lamp relay Condition Continuity Terminal 

12 V direct current supply between terminals
and
. Yes No current supply No
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace stop lamp relay.
Other materials:
Fonction de démarrage à distance du moteur du Nissan Rogue
Informations de base et réglementation
Exemple de configuration
Sur les modèles de Nissan Rogue compatibles, la touche de la clé intelligente permet d'initier le cycle moteur sans présence physique à bord. Si vous aviez réglé la climatisation ou le chauffage avant de quitter votre Niss ...
P044c Egr Volume Control Valve Position Sensor
DTC Description
DTC DETECTION LOGIC DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
P044C
00
EGR SENSOR C
(EGR sensor C circuit low)
Diagnosis condition
Ignition switch ON
Signal (terminal)
EGR volume control valve signal
Threshol ...
Steering Switch Signal B Circuit
Component Function Check
CHECK COMBINATION METER INPUT SIGNAL
CONSULT
Ignition switch ON.
Select “Steering switch input” in “Data monitor” mode of “M&A”.
Check that the function operates normally according to the following conditions:
Condition Value
CONTRO ...