Nissan Rogue (T33) 2021-Present Service Manual: Stop Lamp Relay Circuit
Diagnosis Procedure
CHECK STOP LAMP OPERATION
Check that stop lamp is turned ON/OFF when the brake pedal is depressed/released.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Check stop lamp circuit. Refer to Component Function Check.
CHECK STOP LAMP RELAY FUSE
Check that the following fuse is not blown (open):
| Unit | Location | Fuse No. | Capacity |
|---|---|---|---|
| Ignition switch power supply | Fuse and fusible link box 6 | 116 | 10 A |
Is the fuse blown (open)?
YES>>Replace the blown (open) fuse after repairing the affected circuit if a fuse is blown (open).
NO>>GO TO 3.
CHECK STOP LAMP RELAY POWER SUPPLY CIRCUIT
-
Disconnect stop lamp relay connector.
-
Ignition switch ON.
-
Check voltage between stop lamp relay harness connector and ground.
+ - Voltage
(Approx.)Stop lamp relay Connector Terminal E148 1 Ground Battery voltage 3
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK STOP LAMP RELAY
Check stop lamp relay. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace stop lamp relay.
CHECK STOP LAMP RELAY CONTROL SIGNAL CIRCUIT
-
Ignition switch OFF.
-
Disconnect chassis control module connector.
-
Check continuity between chassis control module harness connector and stop lamp relay harness connector.
Chassis control module Stop lamp relay Continuity Connector Terminal Connector Terminal M32 32 E148 4 Yes -
Check continuity between chassis control module harness connector and ground.
Chassis control module — Continuity Connector Terminal E32 32 Ground No
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace harness.
CHECK STOP LAMP POWER SUPPLY CIRCUIT 1
-
Disconnect rear combination lamp (body side) connector.
-
Check continuity between rear combination lamp (body side) harness connector and stop lamp relay harness connector.
Rear combination lamp (body side) Stop lamp relay Continuity Connector Terminal Connector Terminal RH B102 3 E148 2 Yes LH B90 -
Check continuity between stop lamp relay harness connector and ground.
Stop lamp relay — Continuity Connector Terminal E148 2 Ground No
Is the inspection result normal?
YES>>Replace chassis control module. Refer to Removal and Installation.
NO>>Repair or replace harness.
Component Inspection
CHECK STOP LAMP RELAY
-
Ignition switch OFF.
-
Disconnect stop lamp relay connector.
-
Check continuity between stop lamp relay terminals.
Stop lamp relay Condition Continuity Terminal 

12 V direct current supply between terminals
and
. Yes No current supply No
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace stop lamp relay.
Other materials:
Fuel Pump
Component Inspection
CHECK FUEL PUMP
Turn ignition switch OFF.
Disconnect “fuel level sensor unit and fuel pump� harness connector.
Check the resistance between “fuel level sensor unit and fuel pump� terminals as follows.
Fuel level sensor unit and fuel pump Condition Res ...
Can Fundamental. Basic Inspection. Diagnosis and Repair Work Flow
Diagnosis and Repair Work Flow
Trouble Diagnosis Flow Chart
DESCRIPTIONDETAIL OF TROUBLE DIAGNOSIS FLOW CHARTINTERVIEW WITH CUSTOMER
Interview with the customer is important to detect the root cause of
CAN communication system errors and to understand Nissan Ariya vehicle
condition and sympto ...
Side Radar (front Right) (side Radar Front Rh)
C1ec0-44 Control Unit
DTC Description
DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detection condition
C1EC0
44
Control unit
Diagnosis condition
When ignition switch is ON.
Signal (terminal)
—
Threshold
If side radar front RH ...