Nissan Rogue (T33) 2021-Present Service Manual: P2dfd Purge Pump Performance
DTC Description
DTC DETECTION LOGIC
| DTC No. |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||||
| P2DFD | 00 |
EVAP system purge pump (EVAP system purge pump) |
A | Diagnosis condition | Engine running | |
| Signal (terminal) | LIN communication signal | |||||
| Threshold | The rotation speed of the EVAP canister electric purge pump deviates from the threshold value | |||||
| Diagnosis delay time | 5 seconds | |||||
| B | Diagnosis condition | Ignition switch ON | ||||
| Signal (terminal) | LIN communication signal | |||||
| Threshold | When the voltage from the EVAP canister electric purge pump is above or below the threshold value. | |||||
| Diagnosis delay time | 5 seconds | |||||
POSSIBLE CAUSE
-
EVAP canister electric purge pump
-
Harness or connectors (LIN communication circuit is open or shorted.)
FAIL-SAFE
Not applicable
DTC Confirmation Procedure
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Start the engine.
-
Let engine idle for 5 seconds.
-
Check the DTC.
Is the DTC detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
CHECK HARNESS CONNECTOR FOR HALF-LOCK
-
Turn ignition switch OFF.
-
Check the fitting state of EVAP canister electric purge pump harness connector.
NOTE:
Secure lock mechanism of connector.

Push in male connector in direction of the arrow to lock.
Locked state. -
Turn ignition switch ON.
-
Start the engine and wait at least 1 minute.
Is DTC P2DFD detected again?
YES>>GO TO 2.
NO>>INSPECTION END
CHECK EVAP CANISTER ELECTRIC PURGE PUMP POWER SUPPLY
-
Turn ignition switch OFF.
-
Disconnect EVAP canister electric purge pump harness connector.
-
Turn ignition switch ON.
-
Check the voltage between EVAP canister electric purge pump harness connector and ground.
+ − Voltage
(Approx.)EVAP canister electric purge pump Connector Terminal F105 6 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace error-detected parts.
CHECK EVAP CANISTER ELECTRIC PURGE PUMP GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between EVAP canister electric purge pump harness connector and ECM harness connector.
+ − Continuity EVAP canister electric purge pump Connector Terminal F105 5 Ground Existed -
Also check harness for short to power.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace error-detected parts.
CHECK EVAP CANISTER ELECTRIC PURGE PUMP SIGNAL CIRCUIT
-
Check the continuity between EVAP canister electric purge pump harness connector and ECM harness connector.
EVAP canister electric purge pump ECM Continuity Connector Terminal Connector Terminal F105 4 F72 23 Existed -
Also check harness for short to ground and to power.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace error-detected parts.
REPLACE EVAP CANISTER ELECTRIC PURGE PUMP
-
Replace EVAP canister electric purge pump. Refer to Removal and Installation.
-
Perform DTC confirmation procedure again. Refer to DTC Description.
-
Check the DTC.
Is the DTC displayed again?
YES>>Check intermittent incident. Refer to Intermittent Incident.
NO>>INSPECTION END
Other materials:
Symptom Diagnosis. Intelligent Key Button Operation Has Poor Range (all Keys)
Description
Intelligent Key button operation has poor range.SYMPTOM TABLE (BOTH INTELLIGENT KEYS HAVE THE SAME SYMPTOMS) Door lock operation (remote keyless entry)
Door lock operation (request switch of front/rear/back door) or
trunk/back door open operation (opener switch of trunk/back door p ...
Sunload Sensor
Diagnosis Procedure
CHECK SUNLOAD SENSOR SIGNAL
Ignition switch ON.
Check voltage between A/C amp. harness connector.
A/C amp. Voltage
Connector Terminal
(+) (−)
M55
47
78
Is the inspection result normal?
YES>>
Inspection End.
NO>>
G ...
Basic Inspection. Anti-Pinch Inspection
Description
If any of the following operations are performed, the initialization
is necessary for normal operation of anti-pinch function. Refer to Work
Procedure.
When front power window motor (driver side) replaced.