Nissan Rogue (T33) 2021-Present Service Manual: P00c0 Turbocharger Bypass Control Valve
DTC Description
DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||
| P00C0 | 00 |
Turbocharger/Supercharger Bypass Valve B (Turbocharger/Supercharger Bypass Valve B Control Circuit) |
Diagnosis condition | — |
| Signal (terminal) | — | |||
| Threshold | An excessively low voltage from the turbocharger bypass control valve is sent to ECM. | |||
| Diagnosis delay time | 5 consecutive seconds | |||
POSSIBLE CAUSE
-
Harness or connectors
(Turbocharger bypass control valve circuit is open.)
-
Turbocharger bypass control valve
FAIL-SAFE
Not applicable
DTC CONFIRMATION PROCEDURE
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
TEST CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at ignition switch ON.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Turn ignition switch ON and wait at least 5 seconds.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES>>Proceed to Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
Diagnosis Procedure
TURBOCHARGER BYPASS CONTROL VALVE POWER SUPPLY
-
Turn ignition switch OFF.
-
Disconnect turbocharger bypass control valve harness connector.
-
Turn ignition switch ON.
-
Check the voltage between turbocharger bypass control valve harness connector and ground.
+ − Voltage Turbocharger bypass control valve Connector Terminal F104 1 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 2.
NO>>Perform the trouble diagnosis for power supply circuit.
CHECK TURBOCHARGER BYPASS CONTROL VALVE INPUT SIGNAL CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between turbocharger bypass control valve harness connector and ECM harness connector.
Turbocharger bypass control valve ECM Continuity Connector Terminal Connector Terminal F104 2 F72 26 Existed -
Also check harness for short to power or short to ground.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace error-detected parts.
CHECK TURBOCHARGER BYPASS CONTROL VALVE
Check the turbocharger bypass control valve. Refer to Component Inspection.
Is the inspection result normal?
YES>>Check intermittent incident. Refer to Intermittent Incident.
NO>>Replace turbocharger assembly (do not replace bypass control valve only). Refer to Exploded View.
Other materials:
Symptom Diagnosis. Automatic Back Door Functions Do Not Cancel
Diagnosis Procedure
CHECK “POWER BACK DOOR SETTING” IN COMBINATION METER
Check “Power back door setting” is in the OFF.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Set “Power back door setting” to “OFF”.
REPLACE AUTOMATIC BACK DOOR CONTROL UNIT
Rep ...
Removal and Installation. Drain Hose
Exploded View
Refer to Exploded View.
Removal and Installation
REMOVALFrontRemove headlining. Refer to Removal and Installation.
Remove front drain connector. Refer to Removal and Installation.
Remove front drain hose from moonroof unit assembly.RearRemove headlining. Refer to Removal and Insta ...
Diagnosis and Repair Workflow
Intelligent Around View Monitor
Work Flow
OVERALL SEQUENCE
Reference 1··· Refer to Consult Function.
Reference 2··· Refer to DTC Index.
Reference 3··· Refer to Symptom Table.
DETAILED FLOWINTERVIEW AND SYMPTOM CONFIRMATION
Check the malfunction symptoms by performing th ...