Nissan Rogue (T33) 2021-Present Service Manual: P212d Admission Valve Position Sensor
DTC Description
DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||
| P212D | 00 |
Throttle position sensor/switch (Throttle Position Sensor/Switch "G" Circuit High) |
Diagnosis condition | IGN ON |
| Signal (terminal) | ADM valve position signal | |||
| Threshold |
|
|||
| Diagnosis delay time | 1 second | |||
POSSIBLE CAUSE
-
Harness or connectors (ADM valve circuit is open or shorted.)
-
ADM valve
FAIL-SAFE
Engine Control System
| Fail safe mode | Nissan Ariya Vehicle behavior | |
|---|---|---|
| Device fix mode |
|
|
Stop/Start System
Not applicable
DTC Confirmation Procedure
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Turn ignition switch ON and wait at least 2 seconds.
-
Start engine and let it idle for 5 seconds.
-
Check DTC.
Is DTC detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
CHECK ADM VALVE CONNECTOR
Visually check for ADM valve connector.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair the ADM valve connector.
CHECK ADM VALVE POWER SUPPLY
-
Turn ignition switch OFF.
-
Disconnect ADM valve harness connector.
-
Turn ignition switch ON.
-
Check the voltage between ADM valve harness connector and ground.
+ − Voltage
(Approx.)ADM valve Connector Terminal F93 5 Ground 5 V
Is the inspection result normal?
YES>>GO TO 4.
NO>>GO TO 3.
CHECK ADM VALVE POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between ADM valve harness connector and ECM harness connector.
+ − Continuity ADM valve ECM Connector Terminal Connector Terminal F93 5 F71 84 Existed -
Also check harness for short to power.
Is the inspection result normal?
YES>>Perform the trouble diagnosis for power supply circuit.
NO>>Repair or replace error-detected parts.
CHECK ADM VALVE GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between ADM valve harness connector and ECM harness connector.
+ − Continuity ADM valve ECM Connector Terminal Connector Terminal F93 4 F71 107 Existed
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace error-detected parts.
CHECK ADM VALVE SIGNAL CIRCUIT
-
Check the continuity between ADM valve harness connector and ECM harness connector.
+ − Continuity ADM valve ECM Connector Terminal Connector Terminal F93 6 F72 51 Existed -
Also check harness for short to ground and to power.
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace error-detected parts.
CHECK ADM VALVE
Check the ADM valve. Refer to Component Inspection.
YES>>
Check intermittent incident. Refer to Intermittent Incident.
NO>>Replace ADM valve. Refer to Removal and Installation.
Other materials:
Fuel Injector and Fuel Tube
Exploded View
Fuel rail pressure sensor
High pressure fuel rail insulator
High pressure fuel rail
O-ring (black)
Support disc
Fuel injector
Decoupling element
Valve seat
Retaining ring spring
Holding down appliance
Stud bolt
  ...
B2601-42 Memory Failure for Firmware Over the Air
DTC Description
DTC DETECTION LOGIC DTC No. CONSULT screen terms DTC detected condition
B2601-42
Memory failure for firmware over the air
Diagnosis condition
When ignition switch is ON.
Signal (terminal)
—
Threshold
Errors are detected in the memory for software auto ...
P06e6 Internal Control Module
DTC Description
DESCRIPTIONECM supplies a voltage of 5 V to some of the
sensors systematically divided into 3 groups, respectively.
Accordingly, when a short circuit develops in a sensor power source, a
malfunction may occur simultaneously in the sensors belonging to the
same group as the s ...
