Nissan Rogue (T33) 2021-Present Service Manual: P119e Frp Sensor
DTC Description
DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||
| P119E | 00 |
FRP SEN/CIRC (Fuel Pressure Sensor) |
Diagnosis condition | Engine running at idle |
| Signal (terminal) | Fuel rail pressure sensor signal | |||
| Threshold | Signal voltage from the fuel rail pressure sensor remains at more than 4.06 V | |||
| Diagnosis delay time | 5 seconds or more | |||
POSSIBLE CAUSE
-
Harness or connectors
-
Fuel rail pressure sensor circuit is open or shorted.
-
Sensor power supply 1 is shorted.
-
-
Fuel rail pressure sensor
-
Each sensor, connected with sensor power supply 1 circuit
FAIL-SAFE
Engine Control System
| Fail safe mode | Nissan Ariya Vehicle behavior | |
|---|---|---|
| Traveling control mode | Accelerator angle variation control |
ECM controls the accelerator pedal depression speed to make it slower than actual speed. This causes a drop in accelerating performance and encourages the driver to repair malfunction.
ECM does not control the accelerator pedal releasing speed. |
| Combustion control mode | Stratified charge combustion control at starting | No stratified charge combustion at starting (cold start). |
Stop/Start System
Not applicable
DTC Confirmation Procedure
CHECK DTC PRIORITY
If DTC P119E is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES>>Perform diagnosis of applicable.
-
DTC P0088: Refer to DTC Description.
-
DTC P0090: Refer to DTC Description.
GO TO 2.
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is 11 V or more at idle.
>>
GO TO 3.
PERFORM DTC CONFIRMATION PROCEDURE
-
Start engine and let it idle for at least 1 minute.
-
Check DTC or 1st trip DTC.
Is DTC or 1st trip DTC detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
NOTE:
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0192 or P0193. Be sure to erase the DTC when the diagnosis procedure.
CHECK DTC PRIORITY
If DTC P119E is displayed with DTC P0088 or P0090, first perform the trouble diagnosis for DTC P0088 or P0090.
Is other DTC detected?
YES>>Perform diagnosis of applicable.
-
DTC P0088: DTC Description
-
DTC P0090: DTC Description
GO TO 2.
CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-1
-
Turn ignition switch OFF.
-
Disconnect FRP sensor harness connector.
-
Turn ignition switch ON.
-
Check the voltage between FRP sensor harness connector terminals.
FRP sensor Voltage
(Approx.)Connector + − Terminal F85 1 3 5 V
Is inspection result normal?
YES>>GO TO 7.
NO>>GO TO 3.
CHECK FRP SENSOR POWER SUPPLY-2
Check the voltage between FRP sensor harness connector and ground.
| + | − |
Voltage (Approx.) | |
|---|---|---|---|
| FRP sensor | |||
| Connector | Terminal | ||
| F85 | 1 | Ground | 5 V |
Is inspection result normal?
YES>>GO TO 5.
NO>>GO TO 4.
CHECK FRP SENSOR POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor ECM Continuity Connector Terminal Connector Terminal F85 1 F72 61 Existed
Is inspection result normal?
YES>>Perform trouble diagnosis for power supply circuit.
NO>>Repair or replace malfunctioning part.
CHECK FRP SENSOR GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor ECM Continuity Connector Terminal Connector Terminal F85 3 F72 41 Existed -
Also check harness for short to power.
Is inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace malfunctioning part.
CHECK ECM GROUND CIRCUIT
-
Check the continuity between ECM harness connector and the ground.
ECM Ground Continuity Connector Terminal F72 4 Ground Existed E21 156 157 160 -
Also check harness for short to power.
Is inspection result normal?
YES>>INSPECTION END
NO>>Repair or replace malfunctioning part.
CHECK FRP SENSOR SIGNAL CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between FRP sensor harness connector and ECM harness connector.
FRP sensor ECM Continuity Connector Terminal Connector Terminal F85 2 F72 58 Existed -
Also check harness for short to ground and short to power.
Is inspection result normal?
YES>>GO TO 8.
NO>>Repair or replace malfunctioning part.
CHECK FRP SENSOR
Refer to Component Inspection.
Is inspection result normal?
YES>>INSPECTION END
NO>>Replace FRP sensor. Refer to Exploded View.
Other materials:
2wd. Preparation. Preparation
Preparation
Special Service Tool
Tool number
(TechMate No.)
Tool name Description
KV40104000
( – )
Hub lock nut wrench
a: 85 mm (3.35 in)
b: 65 mm (2.56 in)
Removing and Installing wheel hub lock nut.
KV40107300
( – )
Boot band crimping tool
Installing bo ...
P0532 A/c Refrigerant Pressure Sensor
DTC Description
DTC DETECTION LOGIC DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
P0532
00
REFRIGERANT PRESS SENSOR A
(A/C refrigerant pressure sensor A circuit low)
Diagnosis condition
—
Signal (terminal)
Refrigerant pressure sens ...
Power Supply and Ground Circuit
Ecm
Diagnosis Procedure
CHECK THE BATTERY CABLE
Turn ignition switch OFF.
Check the battery cable for tightening enough.
NOTE:
Check the continuity between the battery cable and the battery terminal.
Is the inspection result normal?
YES>>
GO TO 2
...