Nissan Rogue (T33) 2021-Present Service Manual: P0446 Evap Canister Vent Control Valve
DTC Description
DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||
| P0446 | 00 |
VENT CONTROL VALVE (EVAP System Vent Control Circuit) |
Diagnosis condition | Engine running at idle |
| Signal (terminal) | EVAP canister vent control valve signal | |||
| Threshold | An improper voltage signal is sent to ECM through EVAP canister vent control valve | |||
| Diagnosis delay time | — | |||
POSSIBLE CAUSE
-
Harness or connectors (EVAP canister vent control valve circuit is open or shorted.)
-
EVAP canister vent control valve
-
Hoses (Hoses are connected incorrectly or clogged.)
FAIL-SAFE
Not applicable
DTC Confirmation Procedure
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11 V at idle.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Start engine and wait at least 8 seconds.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
INSPECTION START
Do you have CONSULT?
Do you have CONSULT?
YES>>GO TO 2.
NO>>GO TO 3.
CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT
With CONSULT
-
Turn ignition switch OFF and then turn ON.
-
Select “VENT CONTROL/V” in “ACTIVE TEST” mode of “ENGINE” using CONSULT.
-
Touch “ON/OFF” on CONSULT screen.
-
Check for operating sound of the valve.
Clicking sound should be heard.
Is the inspection result normal?
YES>>GO TO 7.
NO>>GO TO 3.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY
-
Turn ignition switch OFF.
-
Disconnect EVAP canister vent control valve harness connector.
-
Turn ignition switch ON.
-
Check the voltage between EVAP canister vent control valve harness connector and ground.
+ − Voltage EVAP canister vent control valve Connector Terminal C52 1 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 5.
NO>>GO TO 4.
CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect IPDM E/R harness connector.
-
Check the continuity between EVAP canister vent control valve harness connector and IPDM E/R harness connector.
+ − Continuity EVAP canister vent control valve IPDM E/R Connector Terminal Connector Terminal C52 1 F35 78 Existed -
Also check harness for short to ground.
Is the inspection result normal?
YES>>Perform the trouble diagnosis for power supply circuit.
NO>>Repair or replace error-detected parts.
CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between EVAP canister vent control valve harness connector and ECM harness connector.
+ − Continuity EVAP canister vent control valve ECM Connector Terminal Connector Terminal C52 2 E21 149 Existed -
Also check harness for short to power.
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace error-detected parts.
CHECK RUBBER TUBE FOR CLOGGING
-
Disconnect rubber tube connected to EVAP canister vent control valve.
-
Check the rubber tube for clogging.
Is the inspection result normal?
YES>>GO TO 7.
NO>>Clean the rubber tube using an air blower.
CHECK EVAP CANISTER VENT CONTROL VALVE
Check the EVAP canister vent control valve. Refer to Component Inspection.
Is the inspection result normal?
YES>>Check intermittent incident. Refer to Intermittent Incident.
NO>>Replace EVAP canister vent control valve. Refer to Removal and Installation.
Other materials:
U1321-55 Configuration Unfinished
DTC Description
DTC DETECTION LOGIC DTC No.
CONSULT screen terms
(Trouble diagnosis content) DTC detection condition
U1321–55
Config unfinished
(Configuration unfinished)
Diagnosis condition
When ignition switch is ON
Signal (terminal)
—
Threshold
Configuration ...
Symptom Diagnosis. Wiper Deicer Does Not Operate
Diagnosis Procedure
CHECK WIPER DEICER RELAY
Check wiper deicer relay.
Refer to Component Inspection.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace the malfunctioning parts.
CHECK WIPER DEICER
Check wiper deicer.
Refer to Component Function Check.
I ...
Pnsr Branch Line Circuit
Diagnosis Procedure
CHECK CONNECTOR
Ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the terminals and connectors of the power network separate
relay for damage, bend and loose connection (unit side and connector
side).
Is the inspection re ...