Nissan Rogue (T33) 2021-Present Service Manual: Electric Wastegate Control Actuator
Component Inspection
INSPECTION START
Do you have CONSULT?
Do you have CONSULT?
YES>>GO TO 2.
NO>>GO TO 3.
CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR
With CONSULT
-
Turn ignition switch ON and engine stopped.
-
On the CONSULT screen, select “ENGINE”>>“ACTIVE TEST”>>“WASTEGATE ACTUATOR”.
-
Operate “Up” or “Down”, set “W/G ACTUATOR POSITION B1” to 0.002 m, and make a quick short note of value “V1” of “W/G ACTUATOR POSI SEN B1”.
-
Operate “Up” or “Down”, set “W/G ACTUATOR POSITION B1” to 0.006 m, and make a quick short note of value “V2” of “W/G ACTUATOR POSI SEN B1”.
Do the values of “V1” and “V2” change (visually, ACTUATOR SHAFT operates) and “V2” minus “V1” becomes equal to or more than 0.76V?
YES>>INSPECTION END
NO>>Replace Turbocharger Assembly (do not replace electric wastegate control actuator only). Refer to Component Parts Location.
CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR
Without CONSULT
-
Turn ignition switch OFF.
-
Disconnect Wastegate control actuator harness connector.
-
While checking the POSITION SENSOR OUT voltage with an oscilloscope, apply a voltage of 12 V to the positive or negative terminal.
Does ACTUATOR SHAFT visually operate and POSITION SENSOR OUT voltage change?
YES>>INSPECTION END
NO>>Replace Turbocharger Assembly (do not replace electric wastegate control actuator only). Refer to Component Parts Location.
Other materials:
Informations de base
AVERTISSEMENT
Le non-respect des instructions et avertissements relatifs à l’utilisation correcte du détecteur de collision frontale intelligent du Nissan Rogue peut entraîner des blessures graves, voire mortelles.
Le détecteur de collision frontale intelligent sert uniquement à averti ...
Basic Inspection. Diagnosis and Repair Work Flow
Work Flow
OVERALL SEQUENCEDETAILED FLOWGET INFORMATION FOR SYMPTOM
Get detailed information from the customer about the symptom (the
condition and the environment when the incident/malfunction occurs).
Check operation condition of the function that is malfunctioning.
>>
G ...
Dtc/circuit Diagnosis. Interior Room Lamp Power Supply Circuit
Diagnosis Procedure
Provides the interior room lamp power supply. Also cuts the power
supply when the interior room lamp battery saver is activating.CHECK INTERIOR ROOM LAMP POWER SUPPLY FUSE
Ignition switch OFF.
Check that the following fuse is not blown (open):
Signal name Location ...