Nissan Rogue (T33) 2021-Present Service Manual: B272b-11 Center Sensor [fr]
DTC Description
DTC DETECTION LOGIC
| DTC | CONSULT screen items (Trouble diagnosis content) | DTC detection condition | ||
|---|---|---|---|---|
| B272B-11 |
CENTER SENSOR [FR] (Center sensor [FR]) |
Diagnosis condition | When ignition switch is ON | |
| Signal (terminal) | Front sonar sensor signal RH inner | |||
| Threshold | Short to ground | |||
| Diagnosis delay time | 4 seconds or more | |||
POSSIBLE CAUSE
-
Harness and connector between sonar control unit and front sonar sensor RH inner
-
Front sonar sensor signal RH inner
FAIL-SAFE
Stop the obstacle detection function
CONFIRMATION PROCEDURE
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 30 seconds.
-
Turn ignition switch ON and wait at least 30 seconds or more.
-
Select “Self Diagnostic Result” mode of “SONAR” using CONSULT.
-
Check the DTC.
Is DTC “B272B–11” detected?
YES>>Refer to Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
Diagnosis Procedure
CHECK FRONT SONAR SENSOR SIGNAL RH INNER CIRCUIT (SHORT)
-
Turn ignition switch OFF.
-
Disconnect sonar control unit connector and front sonar sensor RH inner connector.
-
Check continuity between sonar control unit harness connector and ground.
| Sonar control unit | Ground | Continuity | |
| Connector | Terminal | ||
| B20 | 1 | Not existed | |
Is the inspection result normal?
YES>>Replace the front sonar sensor RH inner. Refer to Removal and Installation.
NO>>Repair the harness or connector.
Other materials:
Power Supply and Ground Circuit
8ch Can Gateway
Diagnosis Procedure
CHECK FUSE
Check that the following fuse are not blown.
Signal name Fuse No.
Battery power supply
16
Ignition power supply
9
Is the fuse blown (open)?
YES>>
Replace the blown fuse after repairing the affected circuit if a fuse ...
System Description. Diagnosis System (occupant Detection System Control Unit)
CONSULT Function
APPLICATION ITEMCONSULT performs the following functions. Diagnosis mode CGW Status Description
Restricted Mode Diag Test Mode Open Mode
CGW Information
Display
Display
Display
Display the current CGW mode
Enables CGW to switch mode
Data mo ...
B2721-11 Center Sensor [rl]
DTC Description
DTC DETECTION LOGIC DTC CONSULT screen items (Trouble diagnosis content) DTC detection condition
B2721-11
CENTER SENSOR [RL]
(Center sensor [RL])
Diagnosis condition
When ignition switch is ON
Signal (terminal)
Rear sonar sensor signal LH inner
Threshold ...