Nissan Rogue (T33) 2021-Present Service Manual: Anc Branch Line Circuit

Diagnosis Procedure

CHECK CONNECTOR

  1. Turn the ignition switch OFF.

  2. Disconnect the battery cable from the negative terminal.

  3. Check the following terminals and connectors for damage, bend and loose connection (unit side and connector side).

    • Active noise control unit

    • BCM

Is the inspection result normal?

YES-1>>

With type B meter: GO TO 2.

YES-2>>

With type A meter: GO TO 3.

NO>>

Repair the terminal and connector.

CHECK HARNESS CONTINUITY (OPEN CIRCUIT)

  1. Disconnect the connector of BCM.

  2. Check the continuity between the BCM harness connector terminals.

BCM harness connector Continuity
Connector No. Terminal No. Connector No. Terminal No.
B26 87 E29 118 Existed
86 117 Existed

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Check the harness and repair the root cause (Nissan Ariya vehicle CAN communication 2 circuit side). Refer to Diagnosis Procedure.

CHECK HARNESS CONTINUITY (OPEN CIRCUIT)

  1. Disconnect the connector of 8CH CAN gateway.

  2. Check the continuity between the 8CH CAN gateway harness connector terminals.

    8CH CAN gateway harness connector Continuity
    Connector No. Terminal No. Connector No. Terminal No.
    M45 25 M9 55 Existed
    26 56 Existed

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Check the harness and repair the root cause (IT CAN communication 1 circuit side). Refer to Diagnosis Procedure.

CHECK HARNESS FOR OPEN CIRCUIT

  1. Connect the following connectors.

    • BCM (With type B meter)

    • 8CH CAN gateway (With type A meter)

  2. Disconnect the connector of active noise control unit.

  3. Check the resistance between the active noise control unit harness connector terminals.

    Active noise control unit harness connector Resistance (Ω)
    Connector No. Terminal No.
    B92 7 19 Approx. 54 – 66

Is the measurement value within the specification?

YES>>

GO TO 5.

NO>>

Repair the active noise control unit branch line.

CHECK POWER SUPPLY AND GROUND CIRCUIT

Check the power supply and the ground circuit of the active noise control unit. Refer to Diagnosis Procedure.

Is the inspection result normal?

YES (Present error)>>

Replace the active noise control unit. Refer to Removal and Installation.

YES (Past error)>>

Error was detected in the active noise control unit branch line.

NO>>

Repair the power supply and the ground circuit.

    A-Amp. Branch Line Circuit
    Diagnosis Procedure CHECK CONNECTOR Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Check the following terminals and connectors for damag...
    Wl Chg Branch Line Circuit
    Diagnosis Procedure CHECK CONNECTOR Turn the ignition switch OFF. Disconnect the battery cable from the negative terminal. Check the following terminals and connectors for damag...

    Other materials:

    P00fe Evap Control System
    DTC Description This diagnosis detects clogs in the EVAP line between fuel tank and EVAP canister purge volume control solenoid valve.ECM controls EVAP control system as below. ECM monitors EVAP line pressure change to diagnose if there is no clogging between EVAP canister and fuel tank. E ...

    Removal and Installation. Map Lamp
    Exploded View Headlining assembly Map lamp assembly Map lamp housing Bulb Lens Map lamp finisher : Pawl : Metal clip Removal and Installation REMOVALCAUTION: Disconnect the battery negative terminal or remove power circuit fuse when performing t ...

    C10b4-98 Overheat
    DTC Description DTC DETECTION LOGIC DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detection condition C10B4 98 Overheat (Overheat) Diagnosis condition When ignition switch is ON Signal (terminal) — Threshold System is high temperature status. ...