Nissan Rogue manuals

Nissan Rogue Service Manual: SRS air bag warning lamp does not turn on

Nissan Rogue Service Manual / Restraints /  SRS Airbag Control System / Symptom diagnosis / SRS air bag warning lamp does not turn on

AIR BAG Warning Lamp Does Not Turn On

1.CHECK METER FUSE

Check the 10A fuse [No. 13, located in the fuse block (J/B)].

Is the fuse blown? YES >> GO TO 2.

NO >> GO TO 3.

2.REPLACE METER FUSE AND CHECK AGAIN

Replace 10A fuse [No. 13, located in the fuse block (J/B)] and turn ignition switch ON.

Does the fuse blow again? YES >> Replace fuse and harness.

NO >> Inspection End.

3.CHECK HARNESS CONNECTIONS BETWEEN AIR BAG DIAGNOSIS SENSOR UNIT AND COMBINATION METER

Inspect the harness and connectors between the air bag diagnosis sensor unit and the combination meter.

Do the harness or connectors have any visible damage? YES >> Replace harness.

NO >> GO TO 4.

4.CHECK COMBINATION METER

Disconnect the air bag diagnosis sensor unit harness connectors and turn ignition switch ON.

Does AIR BAG warning lamp turn on? YES >> Replace the air bag diagnosis sensor unit. Refer to SR-26, "Removal and Installation".

NO >> Replace the combination meter. Refer to MWI-82, "Removal and Installation".

Symptom diagnosis
...

SRS air bag warning lamp does not turn off
AIR BAG Warning Lamp Does Not Turn Off 1.CHECK CONDITION OF AIR BAG MODULE Inspect for any deployed air bag modules or seat belt pre-tensioners. Are any air bag modules or seat belt pre-tensioner ...

Other materials:

Performance test
Inspection INSPECTION PROCEDURE  Connect recovery/recycling/recharging equipment (for HFC-134a) or manifold gauge.  Start the engine, and set to the following condition. Test condition Maintain test condition until A/C system becomes stable. (Approximately 10 minute ...

On board diagnostic (OBD) system
Diagnosis Description This system is an on board diagnostic system that records exhaust emission-related diagnostic information and detects a sensors/actuator-related malfunction. A malfunction is indicated by the malfunction indicator lamp (MIL) and stored in control module memory as a DTC. ...

Basic inspection
DIAGNOSIS AND REPAIR WORK FLOW Work Flow OVERALL SEQUENCE DETAILED FLOW 1.GET INFORMATION FOR SYMPTOM  Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurs).  Check operation condition of the ...