Nissan Rogue (T33) 2021-Present Service Manual: P26a3 Multi-Way Control Valve Motor
DTC Description
DTC DETECTION LOGIC
NOTE:
If DTC P26A3 is displayed with DTC P26A5, P26A6, and/or P26A7 first perform the trouble diagnosis for DTC P26A5, P26A6, and/or P26A7. Refer to DTC Index.
| DTC |
CONSULT screen terms (Trouble diagnosis content) | DTC detection condition | ||
|---|---|---|---|---|
| P26A3 | 00 |
ENGINE COOLANT BYPASS VALVE (Engine coolant bypass valve A range/performance) |
Diagnosis condition | — |
| Signal (terminal) | — | |||
| Threshold |
ECM detects the following status continuously for 10 seconds or more: Target valve angle - actual valve angle ≥± 5° |
|||
| Diagnosis delay time | 5 consecutive seconds | |||
POSSIBLE CAUSE
-
Harness or connectors
(Multi-way control valve motor circuit is open or shorted.)
-
Multi-way control valve
-
Sensor power supply 1 circuit
FAIL-SAFE
Not applicable
DTC CONFIRMATION PROCEDURE
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
-
Turn ignition switch OFF and wait at least 10 seconds.
-
Turn ignition switch ON.
-
Turn ignition switch OFF and wait at least 10 seconds.
TEST CONDITION:
Before performing the following procedure, confirm that battery voltage is between more than 10 V and less than 16 V at idle.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Turn ignition switch ON and wait at least 10 seconds.
-
Start the engine and let it idle for 60 seconds.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES>>Refer to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
CHECK MULTI-WAY CONTROL VALVE MOTOR OUTPUT SIGNAL CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect multi-way control valve harness connector and ECM harness connector.
-
Check the continuity between multi-way control valve harness connector and ECM harness connector.
Multi-way control valve ECM Continuity Connector Terminal Connector Terminal F106 1 F71 72 Existed 2 71
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace error-detected parts.
CHECK MULTI-WAY CONTROL VALVE MOTOR
Check the multi-way control valve motor. Refer to Component Inspection.
Is the inspection result normal?
YES>>Check intermittent incident. Refer to Intermittent Incident.
NO>>Replace multi-way control valve. Refer to Removal and Installation.
Other materials:
Service Data and Specifications (sds)
General Specifications
BRAKE SYSTEMJAPAN PRODUCTION MODELS WITHOUT ProPILOT Assist 2.1Unit: mm (in) Front brake
Cylinder bore diameter
60.33 (2.3752)
Pad length × width × thickness
123.6 × 53.5 × 10.5 (4.87 × 2.106 × 0.413)
Rotor outer diameter × thickness
296 × 26.0 ( ...
U2a8c-88 Ethernet Circuit
DTC Description
DTC DETECTION LOGIC DTC No. CONSULT screen terms DTC detected condition
U2A8C-88
Ethernet circuit
Diagnosis condition
When ignition switch is ON.
Signal (terminal)
—
Threshold
Lost ethernet communication with AV control unit
Diagnosis delay time ...
Power Supply and Ground Circuit
8ch Can Gateway
Diagnosis Procedure
CHECK FUSE
Check that the following fuse are not blown.
Signal name Fuse No.
Battery power supply
16
Ignition power supply
9
Is the fuse blown (open)?
YES>>