Nissan Rogue (T33) 2021-Present Service Manual: P0108 Barometric Pressure Sensor
DTC Description
DTC DETECTION LOGIC
| DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | ||
| P0108 | 00 |
ABSL PRES SEN/CIRC (Manifold Absolute Pressure/Barometric Pressure Sensor Circuit High) |
Diagnosis condition | Ignition switch ON |
| Signal (terminal) | Manifold absolute pressure (MAP) sensor signal | |||
| Threshold | An excessively high voltage from the sensor is sent to ECM | |||
| Diagnosis delay time | — | |||
POSSIBLE CAUSE
-
Harness or connectors [Manifold absolute pressure (MAP) sensor circuit is open or shorted.]
-
Manifold absolute pressure (MAP) sensor
FAIL-SAFE
| Fail safe mode | Nissan Ariya Vehicle behavior | |
|---|---|---|
| Traveling control mode | Engine output control |
ECM reduces the engine output, according to the rise in engine speed. This reduces the Nissan Ariya vehicle speed to encourage the driver to repair malfunction.
This value is a reference value converted from engine power to Nissan Ariya vehicle speed. Actual power limitation value differs due to the malfunctioning part and driving condition. |
| Device fix mode |
|
|
DTC CONFIRMATION PROCEDURE
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at least 10 seconds before conducting the next test.
>>
GO TO 2.
PERFORM DTC CONFIRMATION PROCEDURE
-
Start engine and let it idle for 10 seconds.
-
Check 1st trip DTC.
Is 1st trip DTC detected?
YES>>Proceed to DTC Diagnosis Procedure.
NO-1>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO-2>>Confirmation after repair: INSPECTION END
DTC Diagnosis Procedure
CHECK GROUND CONNECTION
-
Turn ignition switch OFF.
-
Check ground connection. Refer to Ground Inspection in Refer to Circuit Inspection.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace ground connection.
CHECK MAP SENSOR
Check MAP sensor. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace MAP sensor. Refer to Removal and Installation.
CHECK MAP SENSOR POWER SUPPLY
-
Turn ignition switch OFF.
-
Disconnect MAP sensor harness connector.
-
Turn ignition switch ON.
-
Check the voltage between MAP sensor harness connector and ground.
+ − Voltage
(Approx.)MAP sensor Connector Terminal F86 1 Ground 5 V
Is the inspection result normal?
YES>>GO TO 5.
NO>>GO TO 4.
CHECK MAP SENSOR POWER SUPPLY CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between ECM harness connector and MAP sensor harness connector.
ECM MAP sensor Continuity Connector Terminal Connector Terminal F71 80 F86 1 Existed -
Also check harness for short to power and short to ground.
Is the inspection result normal?
YES>>Perform the trouble diagnosis for ECM power supply circuit. Refer to Diagnosis Procedure.
NO>>Repair or replace error-detected parts.
CHECK MAP SENSOR GROUND CIRCUIT
-
Turn ignition switch OFF.
-
Disconnect ECM harness connector.
-
Check the continuity between ECM harness connector and MAP sensor harness connector.
ECM MAP sensor Continuity Connector Terminal Connector Terminal F71 106 F86 3 Existed -
Also check harness for short to power.
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace error-detected parts.
CHECK MAP SENSOR CIRCUIT
-
Check the continuity between ECM harness connector and MAP sensor harness connector.
ECM MAP sensor Continuity Connector Terminal Connector Terminal F71 120 F86 2 Existed -
Also check harness for short to power and short to ground.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Repair or replace error-detected parts.
Other materials:
Dtc/circuit Diagnosis. B242a-98 Closure Motor
DTC Description
DTC DETECTION LOGIC DTC No.
CONSULT screen items
(Trouble diagnosis content) DTC Detection Condition
B242A-98
Closure motor
(Closure motor)
Diagnosis condition
When back door closure function operate
Signal (terminal)
—
Threshold
When thermal prot ...
Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses
Work Flow
CUSTOMER INTERVIEWInterview
the customer if possible, to determine the conditions that exist when
the noise occurs. Use the Diagnostic Worksheet during the interview to
document the facts and conditions when the noise occurs and any of
customer's comments; Refer to Diagnostic Work ...
Electric Wastegate Control Actuator
Component Inspection
INSPECTION START
Do you have CONSULT?
Do you have CONSULT?
YES>>
GO TO 2.
NO>>
GO TO 3.
CHECK ELECTRIC WASTEGATE CONTROL ACTUATOR
With CONSULT
Turn ignition switch ON and engine stopped.
On the CONSULT screen, select “ENGINE”>>“ACTIVE ...

NOTE: