Nissan Rogue (T33) 2021-Present Service Manual: Engine Oil Temperature Sensor

Component Inspection

CHECK ENGINE OIL TEMPERATURE (EOT) SENSOR

  1. Turn ignition switch OFF.

  2. Disconnect EOT sensor harness connector.

  3. Remove EOT sensor. Refer to Component Parts Location.

  4. Check the resistance between EOT sensor terminals by heating with hot water as shown in the figure.

    EOT sensor Condition Resistance
    Terminal
    1 2 Temperature [°C (°F)] 20 (68) 2.37 – 2.63 kΩ
    50 (122) 0.68 – 1.00 kΩ
    90 (194) 0.236 – 0.260 kΩ

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Replace EOT sensor. Refer to Component Parts Location.

    Engine Oil Pressure Sensor
    Component Inspection CHECK EOP SENSOR Turn ignition switch OFF. Disconnect EOP sensor harness connector. Check resistance between EOP sensor connector terminals. EOP sensor Resi...
    Evap Canister Purge Volume Control Solenoid Valve
    Component Inspection CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE With CONSULT Turn ignition switch OFF. Reconnect all harness connectors disconnected. Disconnect EVA...

    Other materials:

    Symptom Diagnosis. Id Registration Cannot Be Completed
    Description The ID of the tire pressure sensor installed in each wheel cannot be registered in the tire pressure monitoring system. Inspect the tire pressure sensor or the tire pressure monitoring system circuit. Diagnosis Procedure NOTE: The Signal Tech II Tool [– (NI-50190)] can be used ...

    Ignition Signal
    Component Function Check INSPECTION START Turn ignition switch OFF, and restart engine. Does the engine start? YES-1>> With CONSULT: GO TO 2. YES-2>> Without CONSULT: GO TO 3. NO>> Refer to Diagnosis Procedure. CHECK IGNITION SIGNAL FUNCTION-1 With CONSULT Perfor ...

    P2271 Ho2s2
    DTC Description The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/F) sensor 1. The oxygen storage capacity of the three way catalyst (manifold) causes the longer switching time. : 0.71 V To judge the malfunctions of heated oxyge ...