Nissan Rogue (T33) 2021-Present Service Manual: Dtc/circuit Diagnosis :: Wiper Deicer Relay
Component Function Check
CHECK WIPER DEICER RELAY POWER SUPPLY CIRCUIT
CONSULT
-
Ignition switch ON.
-
Select "Front window defogger (passenger side)" and "Front window defogger (driver side)" in "Active test" mode of "BCM".
-
Select “On”.
-
Check that the front window heating wire is getting warmer.
Is the inspection result normal?
YES>>Wiper deicer relay power supply circuit function is OK.
NO>>Refer to Diagnosis Procedure.
Diagnosis Procedure
CHECK WIPER DEICER CIRCUIT
-
Ignition switch ON.
-
Check voltage between wiper deicer relay harness connector and ground.
(+) (–) Condition Voltage
(Approx.)Wiper deicer relay Connector Terminal E54 7 Ground Rear window defogger switch: ON Battery voltage Rear window defogger switch: OFF 0 V
Is the inspection result normal?
YES>>GO TO 4.
NO>>GO TO 2.
CHECK WIPER DEICER CIRCUIT 2
-
Ignition switch OFF.
-
Disconnect wiper deicer relay and fuse block (J/B) connector.
-
Check continuity between wiper deicer relay terminal connector and fuse block (J/B) harness connector.
Wiper deicer relay Fuse block (J/B) Continuity Connector Terminal Connector Terminal E54 8 B32 5Q Yes
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness.
CHECK WIPER DEICER RELAY GROUND CIRCUIT
-
Ignition switch OFF.
-
Disconnect wiper deicer relay connector.
-
Check continuity between wiper deicer relay terminal connector and ground.
| Wiper deicer relay | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| E54 | 9 | Ground | Yes |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK WIPER DEICER RELAY
Check wiper deicer relay.
Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace wiper deicer relay.
CHECK INTERMITTENT INCIDENT
Check intermittent incident.
Refer to Intermittent Incident.
>>
Inspection End.
Component Inspection
CHECK WIPER DEICER RELAY
-
Ignition switch OFF.
-
Disconnect wiper deicer relay.
-
Check continuity between wiper deicer relay terminals.
| Wiper deicer relay | Condition | Continuity | |
|---|---|---|---|
| Terminal | |||
| 6 | 7 | 12 V direct current supply between terminals 8 and 9. | Yes |
| No current supply | No | ||
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace wiper deicer relay.
Other materials:
Diagnosis System (front Camera Unit)
Diagnosis Description
APPLICATION ITEMSCONSULT performs the following functions via CAN communication using front camera unit. Diagnosis mode Description
Self Diagnostic Result
Retrieve DTC from ECU and display diagnostic items
Data Monitor
Monitor the input/output signal of the cont ...
Dlc Branch Line Circuit
Diagnosis Procedure
CHECK CONNECTOR
Turn the ignition switch OFF.
Disconnect the battery cable from the negative terminal.
Check the following terminals and connectors for damage, bend and loose connection (connector side and harness side).
Data link connector
8CH CAN gatew ...
Diagnosis System (combination Meter)
On Board Diagnosis Function
ON BOARD DIAGNOSIS ITEMThe following meter functions can be checked during combination meter self-diagnosis mode:
Pointer sweep of speedometer, tachometer and gauges.
Illumination of color patterns for meter displays.
Illumination of all lamps/LEDs that are ...