MOONROOF
MOONROOF : Diagnosis Procedure
1. PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Refer to RF-24, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".
Is the inspection result normal? YES >> Moonroof system is normal.
NO >> GO TO 2.
2.CHECK MOONROOF SWITCH
Check moonroof switch.
Refer to RF-31, "Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning parts.
3.CONFIRM THE OPERATION
Confirm the operation again.
Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-41, "Intermittent Incident".
NO >> GO TO 1.
SUNSHADE
SUNSHADE : Diagnosis Procedure
1.PERFORM INITILAZATION PROCEDURE
Refer to RF-24, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement".
Is the inspection result normal? YES >> Sunshade system is normal.
NO >> GO TO 2.
2.CHECK MOONROOF SWITCH
Check moonroof switch.
Refer to RF-31, "Diagnosis Procedure".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace the malfunctioning parts.
3.CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal? YES >> Check intermittent incident. Refer to GI-41, "Intermittent Incident".
NO >> GO TO 1.
P2765 input speed sensor B
DTC Description
DTC DETECTION LOGIC
DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
P2765
INPUT SPEED SENSOR B
(Input/Turbine Speed Sensor B Circuit)
When 1 is satisfied and any of 2, 3 or 4 is satisfied and this state
is maintaine ...
Preparation
Special Service Tool
The actual shape of the tools may differ from those illustrated here.
Tool number
(TechMate No.)
Tool name
Description
—
(J-43897-18)
Oxygen sensor thread cutter
Reconditioning the exhaust system threads
before installing ...
Anti-pinch function does not operate
MOONROOF
MOONROOF : Diagnosis Procedure
1. PERFORM INITIALIZATION PROCEDURE
Perform initialization procedure.
Refer to RF-24, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair
Requirement".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Per ...