Nissan Rogue manuals

Nissan Rogue Service Manual: The steering switches are inoperative

Description

One or more of the steering switches to control the information display are inoperative.

Diagnosis Procedure

1.CHECK STEERING SWITCH CIRCUIT

Check steering switch circuit. Refer to MWI-69, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace harness or connector.

2.CHECK STEERING SWITCH RESISTANCE

Check steering switch resistance. Refer to MWI-69, "Component Inspection".

Is the inspection result normal? YES >> GO TO 3.

NO >> Replace steering switch. Refer to AV-65, "Removal and Installation".

3.CHECK SPIRAL CABLE

Check spiral cable for continuity. Refer to MWI-69, "Component Inspection".

Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-82, "Removal and Installation".

NO >> Replace spiral cable. Refer to SR-15, "Removal and Installation".

The meter control switch is inoperative
Description The meter control switches are inoperative when pressed. Diagnosis Procedure 1.CHECK METER CONTROL SWITCH SIGNAL Check the meter control switch signal. Refer to MWI-67, "Diagnosis ...

The ambient temperature display is incorrect
Description The displayed outside air temperature is higher than the actual temperature.  The displayed outside air temperature is lower than the actual temperature.  Outside a ...

Other materials:

Fuse inspection
How To Check If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.  Use fuse of specified rating. Never use fuse of more than specified rating.  Do not partially install fuse; always insert it into fuse holder properly.  Remove fus ...

Removal and installation
FRONT COIL SPRING AND STRUT Exploded View Strut mount insulator Rotary stop Front spring upper rubber seat  Front suspension bound bumper Front spring Front spring lower rubber seat Stabilizer connecting rod Strut Steering knuckle Removal and Installation REMO ...

Interior room lamp control circuit
Description Controls each interior room lamp (ground side) by PWM signal. NOTE: PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming). Component Function Check CAUTION: Before performing the diagnosis, check that the following is normal.  Interior ro ...

В© 2014-2025 Copyright www.nirogue.com