Nissan Rogue manuals

Nissan Rogue Service Manual: Rear wiper auto stop signal circuit

Component Function Check

1. CHECK REAR WIPER (AUTO STOP) OPERATION

CONSULT DATA MONITOR

  1.  Select WIPER of BCM data monitor item.
  2.  Operate the rear wiper.
  3.  Check that RR WIPER STOP changes to ON and OFF linked with the wiper operation.

Check rear wiper (auto stop) operation

Is the inspection result normal? YES >> Rear wiper auto stop signal circuit is normal.

NO >> Refer to WW-49, "Diagnosis Procedure".

Diagnosis Procedure

Regarding Wiring Diagram information, refer to WW-28, "Wiring Diagram".

1. CHECK REAR WIPER MOTOR AUTO STOP CIRCUITS FOR OPEN

  1.  Turn ignition switch OFF.
  2.  Disconnect BCM and rear wiper motor.
  3.  Check continuity between BCM harness connector terminal and rear wiper motor harness connector terminal.

Check rear wiper motor auto stop circuits for open

Is inspection result normal? YES >> GO TO 2.

NO >> Repair or replace harness.

2. CHECK AUTO STOP CIRCUITS FOR SHORT TO GROUND

Check continuity between BCM harness connector terminal and ground.

Check auto stop circuits for short to ground

Is inspection result normal? YES >> Replace BCM. Refer to BCS-75, "Removal and Installation" (with Intelligent Key system) or BCS- 135, "Removal and Installation" (with Intelligent Key system).

NO >> Repair or replace harness.

Rear wiper motor circuit
Component Function Check 1. CHECK REAR WIPER ON OPERATION CONSULT ACTIVE TEST  Select "RR WIPER" of BCM active test item.  While operating the test item, check rear wiper ...

Symptom diagnosis
...

Other materials:

Windshield-washer fluid
Windshield-washer fluid reservoir Fill the windshield-washer fluid reservoir periodically. Add windshield-washer fluid when the low windshield-washer fluid warning light comes on. To fill the windshield-washer fluid reservoir, lift the cap off the reservoir and pour the windshieldwasher ...

P0441 EVAP control system
DTC Description DTC DETECTION LOGIC In this evaporative emission (EVAP) control system, purge flow occurs during non-closed throttle conditions. Purge volume is related to air intake volume. Under normal purge conditions (non-closed throttle), the EVAP canister purge volume control solenoi ...

P084d transmission fluid pressure SEN/SW H
DTC Description DTC DETECTION LOGIC DTC CONSULT screen terms (Trouble diagnosis content) DTC detection condition P084D FLUID PRESS SEN/SW H (Transmission Fluid Pressure Sensor/Switch “H” Circuit High) When all of the following conditions are satisfied and t ...

© 2014-2024 Copyright www.nirogue.com