Special Service Tool
The actual shape of the tools may differ from those illustrated here.
Tool number (TechMate No.) Tool name |
Description |
|
— (J-41425-NIS) Aluminum tube repair kit |
|
Repairing leaks in A/C tube |
— (J-38873-A) Drive plate installer |
|
Installing pulley |
Commercial Service Tool
(TechMate No.) Tool name |
Description |
|
(J-41810-NI) Refrigerant identifier equipment (R- 134a) |
|
For checking refrigerant purity and system contamination |
( — ) Power Tool |
|
Loosening nuts, screws and bolts |
— (J-48710) NISSAN ACR2009 RRR Unit |
|
Refrigerant recovery, recycling and recharging |
— (J-41995) Electronic refrigerant leak detector |
|
Power supply:
|
—
(J-43926)
Refrigerant dye leak detection kit
Kit includes: (J-42220) UV lamp and UV safety goggles (J-41459) Refrigerant dye injector (J-41447) Fluorescent leak detection dye (box of 24, 1/4 ounce bottles) (J-43872) Refrigerant dye cleaner |
|
Power supply:
|
— (J-39183-C) Manifold Gauge Set (with hoses and couplers) |
|
Identification:
|
Service Hoses:
|
|
Hose color:
|
Service couplers
|
|
Hose fitting to service hose:
|
— (J-39699) Refrigerant Weight Scale |
|
For measuring of refrigerant
Fitting size-Thread size
|
— (J-39649) Vacuum Pump (Including the isolator valve) |
|
Capacity:
|
— (J-46534) Trim Tool Set |
|
Removing trim components |
Sealant and/or Oil
Tool number (TechMate No.) Tool name |
Description |
|
— ( — ) HFC-134a (R-134a) Refrigerant |
|
Container color: Light blue
Container marking: HFC-134a (R-
134a)
Fitting size: Thread size
|
— ( — ) ND-OIL 8 |
|
Type: Nippon Denso Oil 8 (ND-OIL 8) Application: HFC-134a (R-134a) |
B0093 front door satellite sensor LH
DTC Logic
DTC DETECTION LOGIC
With CONSULT
CONSULT name
DTC
DTC detecting condition
Repair order
DOOR SATELLITE SENSOR LH
[SENSOR FAIL]
B0093
Front door satellite sensor LH has malfunctioned.
Refer to SRC-70, "Diagnosis Procedure".
...
Audio operation precautions
Compact disc (CD) player
CAUTION
Do not force a compact disc into the CD
insert slot. This could damage the CD
and/or CD player.
Trying to load a CD with the CD door
closed could damage the CD and/or CD
player.
Only one CD can be loaded into ...
Standardized relay
Description
NORMAL OPEN, NORMAL CLOSED AND MIXED TYPE RELAYS
Relays can mainly be divided into three types: normal open, normal closed and
mixed type relays.
TYPE OF STANDARDIZED RELAYS
...