Nissan Rogue manuals

Nissan Rogue Service Manual: Inspection and adjustment

ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL

ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Description

If any of the following work has been done Initial setting is necessary.

ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement

INITIALIZATION PROCEDURE

  1.  Disconnect battery minus terminal or main power and window door lock/unlock switch connector. Reconnect it after a minute or more.
  2.  Turn ignition switch ON.
  3.  Operate power window switch to fully open the window. (This operation is unnecessary if the window is already fully open)
  4. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed position, keep pulling the switch for 2 seconds or more.
  5.  Initializing procedure is completely.
  6.  Inspect anti-pinch function.

CHECK ANTI-PINCH FUNCTION

  1.  Fully open the door window.
  2.  Place a piece of wood near fully closed position.
  3.  Close door glass completely with AUTO-UP.

CAUTION:

  1.  Auto-up operation
  2.  Anti-pinch function

ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT

ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description

Refer to PWC-27, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Description".

ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement

Refer to PWC-27, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special Repair Requirement" for initialization procedure and check anti-pinch function.

Diagnosis and repair workflow
Work Flow OVERALL SEQUENCE DETAILED FLOW 1. OBTAIN INFORMATION ABOUT SYMPTOM Interview the customer to obtain as much information as possible about the conditions and environment under whic ...

DTC/circuit diagnosis
...

Other materials:

DTC/circuit diagnosis
DOOR MIRROR REMOTE CONTROL SWITCH (MIRROR SWITCH/ CHANGEOVER SWITCH) Component Inspection 1.CHECK MIRROR SWITCH & CHANGEOVER SWITCH  Turn ignition switch OFF.  Disconnect door mirror remote control switch connector.  Check door mirror remote control switch. Is th ...

Basic inspection
DIAGNOSIS AND REPAIR WORK FLOW Work Flow OVERALL SEQUENCE DETAILED FLOW 1.GET INFORMATION FOR SYMPTOM  Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurs).  Check operation condition of the ...

Front wiper auto stop signal circuit
Component Function Check 1. CHECK FRONT WIPER (AUTO STOP) SIGNAL  Select FR WIPER STOP of BCM (WIPER) data monitor item.  Operate the front wiper.  Check that FR WIPER STOP changes from ON to OFF according to the wiper position Is the inspection result normal? YES ...