Nissan Rogue manuals

Nissan Rogue Service Manual: VDC off indicator lamp

Component Function Check

1.CHECK VDC OFF INDICATOR LAMP FUNCTION (1)

Check that VDC OFF indicator lamp in combination meter turns ON for 1 second after ignition switch is turned ON.

CAUTION: Never start the engine. Is the inspection result normal? YES >> GO TO 2.

NO >> Proceed to BRC-123, "Diagnosis Procedure".

2.CHECK VDC OFF INDICATOR LAMP FUNCTION (2)

Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated.

Is the inspection result normal? YES >> Inspection End.

NO >> Check the VDC OFF switch system. Refer to BRC-117, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT

Perform the trouble diagnosis for ABS actuator and electric unit (control unit) power supply and ground circuit.

Refer to BRC-123, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace error-detected parts.

2.CHECK VDC OFF INDICATOR LAMP SIGNAL

With CONSULT

  1.  Select “ABS”, “DATA MONITOR” and “OFF LAMP” according to this order.
  2.  Turn the ignition switch OFF.
  3.  Check that data monitor displays “On” for 1 second after ignition switch is turned ON, and then changes to “Off”.

CAUTION: Never start the engine. Is the inspection result normal? YES >> GO TO 3.

NO >> Replace the ABS actuator and electric unit (control unit). Refer to BRC-136, "Removal and Installation".

3.CHECK VDC OFF INDICATOR LAMP SIGNAL

With CONSULT

  1.  Select “ABS”, “DATA MONITOR” and “OFF LAMP” according to this order.
  2.  Check that data monitor displays “On” or “Off” each time when VDC OFF switch is operated.

Is the inspection result normal? YES >> Replace the combination meter. Refer to MWI-82, "Removal and Installation".

NO >> Check the VDC OFF switch system. Refer to BRC-117, "Diagnosis Procedure".

VDC warning lamp
Component Function Check 1.CHECK VDC WARNING LAMP FUNCTION Check that VDC warning lamp in combination meter turns ON for 1 second after ignition switch is turned ON. CAUTION: Never start the e ...

Symptom diagnosis
...

Other materials:

Refrigerant
Description CONNECTION OF SERVICE TOOLS AND EQUIPMENT Shut-off valve A/C service valve Recovery/recycling/recharging equipment  Refrigerant container (HFC-134a) Weight scale Vacuum pump Manifold gauge set  Preferred (best) method Alternative method &n ...

Front door glass
Exploded View Front door Front regulator Front power window motor Front door glass rear run Front door glass front run Front door glass  Front door glass rubber run Removal and Installation REMOVAL  Remove the front door finisher. Refer to INT-15, "Remov ...

Wiring diagram
NAVIGATION WITH BOSE Wiring Diagram ...