Component Parts Location
No. |
Component part |
Description |
1 | Combination meter (Charge warning lamp) | The IC regulator warning function activates to illuminate the charge
warning
lamp if any of the following symptoms occur while generator is
operating:
|
2 | ECM | ECM transmits a target power generation voltage signal received from IPDM E/R to the generator via LIN communication. In addition, the ECM controls the charge warning lamp via CAN communication to the combination meter. |
3 | IPDM E/R | The IPDM E/R receives the generator signals via CAN communication from ECM. |
4 | Generator (IC voltage regulator) | IC voltage regulator controls the power generation voltage by the
target
power generation voltage based on the received signal.
When there is no power generation command signal, the generator performs the normal power generation according to the characteristic of the IC voltage regulator. |
Preparation
Special service tools
The actual shape of the tools may differ from those illustrated here.
Tool number
(TechMate No.)
Tool name
Description
—
(J-48891)
Spark plug socket
Removing and installing spark plug
KV10111100
(J-37228)
Seal cutter ...
Diagnosis and repair work flow
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
1.INTERVIEW THE CUSTOMER FOR THE SYMPTOM
Interview the customer for the symptom (the condition and the environment
when the incident/malfunction
occurs).
>> GO TO 2.
2.CHECK SYMPTOM
Check the symptom from the customer information.
> ...
Windshield-washer fluid
Windshield-washer fluid reservoir
Fill the windshield-washer fluid reservoir periodically.
Add windshield-washer fluid when the low
windshield-washer fluid warning light comes on.
To fill the windshield-washer fluid reservoir, lift
the cap off the reservoir and pour the windshieldwasher ...