Nissan Rogue manuals

Nissan Rogue Service Manual: ABC warning lamp

Component Function Check

1.CHECK ABS WARNING LAMP FUNCTION

Check that ABS warning lamp in combination meter turns ON for 1 second after ignition switch is turned ON.

CAUTION: Never start the engine.

Is the inspection result normal? YES >> Inspection End.

NO >> Proceed to BRC-119, "Diagnosis Procedure".

Diagnosis Procedure

1.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT

Perform the trouble diagnosis for ABS actuator and electric unit (control unit) power supply and ground circuit.

Refer to BRC-119, "Diagnosis Procedure".

Is the inspection result normal? YES >> GO TO 2.

NO >> Repair or replace error-detected parts.

2.PERFORM SELF-DIAGNOSIS

With CONSULT

  1.  Turn the ignition switch OFF → ON.

CAUTION:

  1.  Repeat step 1 two or more times.
  2.  Perform self-diagnosis for “ABS”.

Is any DTC detected? YES >> Check the DTC. Refer to BRC-55, "DTC Index".

NO >> GO TO 3.

3.CHECK ABS WARNING LAMP SIGNAL

With CONSULT

  1.  Select “ABS”, “DATA MONITOR” and “ABS WARN LAMP” according to this order.
  2.  Turn the ignition switch OFF.
  3.  Check that data monitor displays “On” for 1 second after ignition switch is turned ON and then changes to “Off”.

CAUTION: Never start the engine. Is the inspection result normal? YES >> Replace the combination meter. Refer to MWI-82, "Removal and Installation".

NO >> Replace the ABS actuator and electric unit (control unit). Refer to BRC-136, "Removal and Installation".

VDC off switch
Component Function Check 1.CHECK VDC OFF SWITCH OPERATION Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated. Is the inspection result normal? ...

Brake warning lamp
Component Function Check 1.CHECK BRAKE WARNING LAMP FUNCTION Check that brake warning lamp in combination meter turns ON for 1 second after ignition switch is turned ON. CAUTION: Never start t ...

Other materials:

Filament
Inspection and Repair INSPECTION  When measuring voltage, wrap tin foil around the top of the negative probe. Then press the foil against the wire with your finger. Attach probe circuit tester (in Volt range) to middle portion of each filament. If a filament is b ...

Service data and specifications (SDS)
General Specifications Preload Torque Backlash Companion Flange Runout ...

Abbreviations
Abbreviation List The following ABBREVIATIONS are used: ...