Nissan Rogue (T33) 2021-Present Service Manual: Symptom Diagnosis :: Door Does Not Lock/unlock and Engine Does Not Start (one I-Key/req Sw/push Sw)
Description
All doors do not lock/unlock using door request switch and engine does not start when push-button ignition switch is pressed while carrying Intelligent Key. (One Intelligent Key has the symptom, other keys operate normally.)
SYMPTOM TABLE (ONE INTELLIGENT KEY HAS THE SYMPTOM, OTHER KEYS OPERATE NORMALLY)
| Door lock operation (remote keyless entry) | Door lock operation (request switch of front/rear/back door) or trunk/back door open operation (opener switch of trunk/back door panel) | Engine started with push-button ignition switch operation (Intelligent Key is within the detection area of inside key antenna) | Engine started with push-button ignition switch operation (registered Intelligent Key placed next to push-button ignition switch) | Unlock operation when approaching the Nissan Ariya vehicle, lock operation when away from the vehicle (registered Intelligent Key is within the detection area of outside key antenna) |
|---|---|---|---|---|
| NG | NG | No crank, No start | OK | OK |
DIAGNOSIS PROCEDURE
Refer to Diagnosis Procedure.
Diagnosis Procedure
CHECK INTELLIGENT KEY SYSTEM SYMPTOM TABLE
Check Intelligent Key system symptom table.
Refer to Diagnosis Procedure.
>>
GO TO 2.
CHECK INTELLIGENT KEY
Check the inside of the Intelligent Key for rust or corrosion by water. Simultaneously check the internal circuits for damage. Squeeze, twist or bend the Intelligent Key and check the functionality again. Is the Intelligent Key operating normally?
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace Intelligent Key.
CHECK INTELLIGENT KEY BATTERY
Check the Intelligent Key battery.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Replace Intelligent Key battery. Refer to Removal and Installation.
REGISTER INTELLIGENT KEY
-
Register the Intelligent Key again.
-
Check operation after replacement.
Is the inspection result normal?
YES>>Inspection End.
NO>>GO TO 5.
REPLACE INTELLIGENT KEY
-
Replace the Intelligent Key and perform registration again.
-
Check operation after replacement.
Is the inspection result normal?
YES>>Inspection End.
NO>>GO TO 6.
REPLACE INTELLIGENT KEY UNIT
-
Replace Intelligent Key unit. Refer to Removal and Installation.
-
Confirm the operation after replacement.
Is the inspection result normal?
YES>>Inspection End.
NO>>Check intermittent incident. Refer to Intermittent Incident.
Other materials:
Ecu Diagnosis Information. Passenger Door Mirror Control Module
Reference Value
TERMINAL LAYOUTPHYSICAL VALUES
Terminal No.
(Wire color) Description Condition
Value
(Approx.)
(+) (−) Signal name Input/Output
1
(BR)
Ground
Door mirror sensor (passenger side) left/right signal
Input
Door mirror RH position
Change between 6 V ( ...
Hands on detection
Basic information
When Steering Assist is activated, the vehicle monitors the driver's steering wheel operation using capacitive and torque sensors in the steering wheel. When ProPILOT Assist is operating in hands-on (green) mode and the steering wheel is not operated, or the driver removes their ha ...
U2259 Can Comm Circuit
DTC Description
DTC DETECTION LOGIC DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
U2259
87
CAN comm err (steering control unit)
[CAN comm err (steering control unit)]
Diagnosis condition
Ignition switch ON
Signal (terminal)
CAN commu ...